Specifications
CP2215 Quick Start Guide 30
020-101295-01 Rev. 2 (05-2014)
Lamp
The ballast is power regulated and has a maximum current of 97A. Therefore the maximum power
specification for a given lamp may not be achievable until the lamp has aged, since lamp voltage
increases with hours of use.
Projectors typically force a 10 minute cool down period. Make sure you do not re-strike the lamp
any sooner than 2 minutes into this cool down period since hot re-strikes reduce lamp life.
Physical Specifications
Item Description
Type Xenon Short Arc Lamp
Power (software adjustable)
CXL-14M (1.4kW)
1000W min.(50%), 1430W nom., 1600W max. (110%)
CDXL-18SD (1.8kW)
1000W min.(50%), 1800W nom., 1900W max. (110%)
CDXL-20SD (2.0kW)
1000W min.(50%), 2000W nom., 2100W max. (110%)
CDXL-23S (2.3kW)
1000W min.(50%), 2200W nom., 2300W max. (110%)
Average Life
CDXL-14M - 3000 hours
CDXL-18SD - 1500 hours
CDXL-20SD - 1500 hours
CDXL-23S - 1000 hours
Wait time between lamp strikes 2 minutes minimum
Warm up time to full brightness 20 minutes maximum
Item Description
Size (L x W x H)
(without lens, with feet at minimum
length)
665 mm (26.18 inches) x 688 mm (27.08 inches) x 395 mm
(15.55 inches)
Weight
As installed with lens:
55 kg (121 lbs)
Shipping (includes packaging)
65 kg (143 lbs)
Operating Position
Rotation about projection axis
± 15 degrees maximum
Tilt of projection axis from horizontal
± 15 degrees maximum